First, safety performance of aluminum alloy cable
1. Historical practice proves that
Aluminum alloy cable word in 1968, the United States research and development, the use of 44 years, the use of the product has been quite common, North America *** market share reached 80%. After 44 years of practice, the use of aluminum alloy cable has never occurred any failure, is safe.
2. Testing and certification
Aluminum alloy cable through the United States UL, Canada CUL, Australia SAI GLOBAI international authority testing certification and China *** wire and cable testing center, ** Wuhan High voltage Research Institute, *** fireproof building materials quality supervision and inspection center and other authority testing certification, Aluminum alloy elevators meet the requirements of CSA standard C22.2 Section 38 for ACM alloy conductors, and the performance requirements of GB/T 12706.1-2008 and IEC 60502.1***, UL for AA8000 series related standards, And in full compliance with the upcoming "Rated voltage 0.6/1kV aluminum alloy conductor crosslinked polyethylene insulated Power cable" NB/T XXXXX-XXXX standard requirements.
3, aluminum alloy composition
★ Aluminum alloy conductor composition with rare earth and iron alloy elements, greatly improve the conductivity and linking properties, after boration and rare earth treatment of AA8000 series aluminum alloy conductivity significantly improved, and the metallostructure depends on the second phase of the metal compound dispersion distribution to stabilize the subcrystalline structure to improve the strength. Due to the low solubility of the added elements such as Fe in Al, they do not reduce the conductivity much, but there are many dispersing second phase to improve the strength. After large deformation processing, they undergo annealing recovery treatment, showing high strength and excellent comprehensive performance of creep resistance. In the case of current overload, iron elements play a continuous linking role. The aluminum alloy conductor will not creep.
★ Creep is very harmful to the cable. If the cable is creeped, the contact point of the original compression will become loose, and the reduction of pressure will make the contact resistance increase rapidly by orders of magnitude. After the current flows through, the contact will be overheated. It is very important to solve the cable creep problem.
★ Creep: metal in a certain temperature, external force and self-weight under the action, with the passing of time, will slowly produce can not recover the *** deformation, this phenomenon is called creep.
4, flame retardant performance
Aluminum alloy cable insulation material using flame retardant XLPE material, the structure of the self-locking armored structure, heat dissipation performance is far better than the ordinary structure of PVC, can quickly heat dissipation, after the flame disappeared the flame can be quickly extinguished, will not burn other materials, flame retardant performance is excellent. Aluminum alloy cable adopts new materials and new technology, which can ensure safer use.
Second, the electrical performance of aluminum alloy cable
1. Cable carrying capacity
★ When the cross-sectional area of aluminum alloy conductor is 1.5 times that of copper, aluminum alloy conductor and copper conductor have the same electrical performance, and achieve the same carrying capacity, resistance value and line loss.
★ The resistance of aluminum alloy is between aluminum and copper, higher than copper, but slightly lower than aluminum, under the same load flow premise, the weight of the same length of aluminum alloy conductor is only half of copper. If the conductivity of copper is 100%IASC, the conductivity of aluminum alloy conductor is 62.5%IACS, the specific gravity of aluminum alloy is 2.71g/cm3, and the specific gravity of copper is 8.9g/cm3.
2. The resistance of copper per unit weight is the same as that of aluminum alloy per unit mass. Therefore, when the cross-sectional area of aluminum alloy conductor is 1.5 times that of copper, its electrical performance is the same, that is, it achieves the same carrying capacity, resistance value and line loss as copper.
★ There are many factors affecting the carrying capacity of power cable, such as: line characteristics (such as working electricity, current type, frequency, load factors); Structure of wire and cable (such as conductor core structure, number of cores, type of insulation material, shielding layer and inner and outer sheath layer structure and material, total outer diameter); Laying conditions (such as air laying, pipeline laying, directly buried laying, underground channel laying, underwater laying); Conductor core *** Allowable operating temperature and ambient conditions (such as air and soil temperature, soil thermal resistance coefficient, proximity effect of surrounding heat source).
2. Reduce the external section of the cable
Aluminum alloy cable production process, our company uses the world's best concentric stranded wire, the conductor filling coefficient can reach 93%. And aluminum alloy cable is made of XLPE insulation material, this insulation only needs to be 2/3 of the thickness of PVC material can far exceed the conventional insulation performance. The filling coefficient of copper can generally only reach about 88%, such as PVC insulation, so the outer diameter of aluminum alloy cable only increases within 11% on the basis of copper cable, you can have the electrical performance of copper cable. Clearly, the use of aluminum cable does not need to change the original use of copper cable pipe design. The size of the laying pipe in general electrical design is 150% of the copper cable. If the capacity is considered, the size of the laying pipe is increased to 200% of the copper cable, so it is not a problem to wear the pipe.
3, reduce line loss
Non-magnetic material, does not produce eddy current, can reduce the loss of the line. The 5000 series aluminum alloy strip used in the self-locking armor of aluminum alloy cable is non-magnetic material, which will not produce eddy current even in the unbalanced three-phase current and can reduce the line loss.
3. Mechanical properties of aluminum alloy cable
1. Extension performance of aluminum alloy cable
Elongation is an important index of the mechanical properties of conductors and an important symbol of the quality of products and their ability to withstand external forces. It is also an important index to test the mechanical properties of cable conductors. The elongation of aluminum alloy cable conductor after annealing can reach 30%, while the elongation of copper cable is about 25% and that of aluminum cable is 15%. It is an important index that can replace aluminum cable and copper cable.
2. Flexibility of aluminum alloy cable
Torsion test, mainly test the toughness of metal wire, toughness is better, can withstand the number of torsion. A fatal defect of aluminum core cable is high brittleness. As long as several times of torsion at a certain Angle are installed, the conductor is easy to crack, and the crack will heat and corroded, which is an important cause of fire. The use of aluminum alloy cable, because of its toughness, will not produce cracks, in the installation of safety risks to reduce.
3. Bending performance of aluminum alloy cable
Bending test: The main test of metal bending resistance. Uneven or brittle materials have poor bending resistance.
According to the GB/T 12706-2008 standard on the bending radius of copper cable installation, the bending radius of copper cable is (100~20) times the cable diameter, and the bending radius of aluminum cable is 7 times the cable diameter. The use of aluminum cable can reduce the layout space, easier to lay, and reduce the installation cost.
4. Rebound performance of aluminum alloy cable
The practice shows that when the copper cable and aluminum cable are bent 90 degrees at room temperature, the rebound Angle of aluminum cable is 60% larger than that of copper cable after the stress is released. Because aluminum alloy cable has no memory, so the rebound performance is better than copper cable, in the installation process of the terminal connector is easy to press, increase its tightness, improve the connection stability.
Four, aluminum alloy cable service life
1. There are two main types of conductor corrosion: chemical corrosion and electrochemical corrosion;
★ Chemical corrosion: metal in the atmosphere and oxygen, chlorine, sulfur dioxide, hydrogen sulfide and other gases under the action of corrosion.
The metal surface reacts with oxygen to form different metal oxides.
Aluminum surface contact with the atmosphere can form a dense continuous oxide film, its molar volume is about 30% larger than aluminum. This oxide film is under compressive stress and forms immediately when it is destroyed. In the general atmosphere, the oxide film thickness on the surface of aluminum is rather thin. The thickness is a function of temperature and ranges from (2.5 to 5.0)nm at room temperature. The oxide film formed in the steam is thicker. At room temperature of 100% relative humidity, the thickness of the oxide film is about 1 times that of the dry atmosphere. In a wet environment, the oxide film is compound, pure on the aluminum side and containing hydroxyl compounds on the outer layer. At high temperature, more complex oxide film is formed on the surface of aluminum alloy, and the growth of oxide film is not a simple function of time.
★ Electrochemical corrosion: It refers to the corrosion process of metal formed after the galvanic cell is composed of metal and medium. When two metals with different electrode potentials are connected and there is water or other electrolytes in between, a current will be generated between the two metals to form a galvanic cell. One metal is at a positive potential and the other is at a negative potential. The metal at negative potential accumulates continuously in ionic state through the electrolyte towards the metal at positive potential. The metal at negative potential gradually loses and destroys, forming electrochemical corrosion. The greater the difference between the electrode potentials of two metals, the stronger the electrochemical corrosion. The higher the temperature, the more serious the corrosion of the metal.
Different metals have different electrode potentials. The order of electrode potential of several metals in common use is:
Order Ag Cu Pb Sn Fe Zn Al
Potential + 0.8 + 0.334-0.122-0.16-0.44-0.76-1.33
The larger the negative electrode potential of the metal, the stronger the tendency to become ions into the electrolyte, that is, the more susceptible to corrosion. The negative electrode potential of aluminum is larger, but its surface often has a protective layer of oxide film, which can improve its corrosion resistance.
The addition of rare earth elements in aluminum alloy, he can play a purification, improve the purity, fill the surface defects, refine the grain, reduce segregation, eliminate micro unevenness and lead to local corrosion, but also bring aluminum electrode potential negative shift, with sacrificial anode effect and excellent conductivity, thus greatly improving the corrosion resistance of aluminum. For Cl- in Marine environment and S, H2S+CO2 in petroleum and chemical environment, this material has a unique anti-corrosion mechanism. The strong reducing property of rare earth metals can effectively combine and interact with the strong oxidation property of S, H2S and Cl- to form stable compounds (Cl- and rare earth aluminum alloy to form stable coordination compounds), organically unify the oxides and reduction processes in chemical reactions, interact with each other, and fundamentally cut off S, H2S. The corrosion damage caused by oxidation activities of Cl- and other corrosive media has completely solved the problem that has not been well solved in the world including the United States.
2. Insulation part
★ The carrying capacity of the power cable refers to the maximum current allowed through the conductor at the maximum allowable working temperature. When re-designing and selecting cables, the heat generated by the loss of each part of the cable should not exceed the allowable temperature of the cable. In most cases, the transmission capacity of the cable is determined by the maximum temperature limit of the cable. The allowable temperature of the cable mainly depends on the thermal aging performance of the insulation materials used, because the working temperature of the cable is too high, the aging of the insulation materials will be accelerated. Cable service life is shortened. If the cable runs below the allowable temperature, the cable will work safely for 30 years.
★XLPE crosslinked polyethylene insulating material, polyethylene is a linear molecular structure, easy to deformation at high temperature. Polyethylene with excellent electrical properties is processed to form a network molecular structure. This network structure not only maintains the unique electrical properties of polyethylene, but also has strong deformation resistance even at high temperature.
★ The excellent anti-aging characteristics of crosslinked polyethylene and super heat resistant deformation determine the normal operating temperature (90℃), short time failure (130℃) and short circuit (250℃) conditions can allow large current through. Because its operating temperature is 20℃ higher than PVC, it has excellent thermal aging resistance, increase the aging resistance of insulation, and greatly increase the life.
Five, the economy of aluminum alloy cable
★ Direct purchasing cost
Aluminum alloy cable and copper cable price comparison: aluminum alloy cable has superior safety performance, electrical performance, mechanical performance and longer service life under the premise, aluminum alloy cable price is only about 75% of copper cable.
★ Installation cost is reduced
★ Save installation cost: Aluminum alloy cable is easy to install because of its good bending and light weight.
Aluminum alloy cable installation and laying without bridge, no pipe, can save a lot of installation materials, installation cost can be reduced (20~50)%.